Only a dot (.) is allowed as the decimal separator. Do not use a comma (,).
Registration Errors
Error Message
How to Fix It
A comma appears in your file as a decimal separator. Change it to a dot.
Registration Warnings
Error Message
Involved Column
How to Fix It
Quantity must be numeric and positive
VOLUME
In Administration, edit the quantity to use this format: 5.5.
Concentration must be null, numeric, and positive
CONCENTRATION
In Administration, edit the concentration to either delete or update it to this format: 5.5.
Unknown quantity unit
QUANTITY_UNIT
In Core Administration, go to the unit section to find the list of registered units. Select the desired unit or create a new one if you have the necessary rights.
Unknown concentration unit
CONCENTRATION_UNIT
In Core Administration, go to the unit section to find the list of registered units. Select the desired unit or create a new one if you have the necessary rights.
Unknown solvent
SOLVENT_NAME
In Sample Administration, go to the solvent section to find the list of registered solvents. Select the desired solvent or create a new one if you have the necessary rights.
A full valid position is required
ROW_ALPHA
In Administration, delete the involved plate, correct the file, and submit it in a new job.
A full valid position is required
COLUMN_INDEX
In Administration, delete the involved plate, correct the file, and submit it in a new job.
Several vials found in this rack position.
RACK_BARCODE, ROW_ALPHA and COLUMN_INDEX
From the Administration, delete the involved plate, correct the file and submit it in a new job again.
There is another sample at this position
From the Administration, remove enough sample in order to have only one per container (either well or vial).
Too many samples (found X samples) in the container (selected format: X)
From the Administration, remove enough sample in order to have only one per container (either well or vial) OR edit the selected container format to be consistent with the number of samples.
Another container has the same name (in pending list or in inventory)
PLATE_BARCODE, RACK_BARCODE, VIAL_BARCODE
From the Administration, edit the container name to be unique.
Container format is not an integer
From the Administration, edit the format to have this format: 96
Unknown container format
CONTAINER_FORMAT
Edit the container format to match a valid format in Reference Data.
Unknown Plate library
PLATE_LIBRARY
Edit the plate library to match a valid entry in Reference Data.
Incorrect rack position
RACK_POSITION
Edit the rack position to match the expected format for the selected rack type.
Incorrect well position according to the plate format.
From the Administration, delete the wells with incorrect positions.
Unknown Control Layout.
The control layout doesn't exist in Reference Data: add it or select an existing one by editing the container.
Incorrect control layout size according to the plate format.
The control layout and the plate format are incompatible. Edit one of them to be consistent.
Registration warnings on Annotations
Error Message
How to fix it
Unknown annotation.
The annotation doesn't exist anymore in Reference Data. From Reference Data, create the annotation or delete it.
Multiple annotations with the same name.
There are multiple annotations with the same name for the same container. Delete them in order to only keep one.
The value can''t be empty.
Fill the annotation value by editing the annotation or delete it.
The value is supposed to be a number.
Edit the annotation and enter a number instead of other characters.
The value is not contained in the control vocabulary of the annotation.
Edit the annotation and select a controlled value or from the Reference Data app, add a new controlled value to the annotation.