--- title: "Tutorial - Combine Source" slug: "tutorial-combine-source" updated: 2026-09-09T14:02:55Z published: 2026-09-09T14:02:55Z canonical: "docs.discngine.com/tutorial-combine-source" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.discngine.com/llms.txt > Use this file to discover all available pages before exploring further. # Tutorial - Combine Source ## Introduction In this tutorial, you will combine the content of four 96-well plates into 384-well plates as illustrated below. ![Plate Reformatting combine replicates](https://cdn.document360.io/dde9293e-c107-4b3e-9774-9c9c296ed970/Images/Setting/sample-plate-reformatting-combine-replicates.png?sv=2026-02-06&spr=https&st=2026-11-11T10%3A57%3A36Z&se=2026-11-11T11%3A57%3A36Z&sr=c&sp=r&sig=A2qOD%2BEQ8E1g2fvd760Nb717Ywd1EEWaYR2IoZDOVik%3D) ## Prerequisites Required permissions and setup **Sample Processing** role is required to access this workflow. **Required system configuration:** - Container Types: `Greiner PP96V`,`Greiner PP384V`, - Container Usage `Inventory`, These should exist by default in the Sample application. ### Items Containers and locations created from Discngine Sample’s automation will be used: - 96-well plates “PTEST001” to “PTEST004” - Location “Paris" Automation is running during installation if “example_dataset” is set to true in the configuration file. ## Workflow ### Job Initialization [Create a new job](/public/docs/jobs-overview#create-a-job) and select the `Plate Reformatting` workflow. ### Requesting - Select **Plate** as Source Type - Select **Generate New Barcode** as Target Plate Barcode - Choose **Greiner PP384V** as Target Plate Type - Specify Request from **Text** - Copy/paste the plate name in the text area: **PTEST001:PTEST002:PTEST003:PTEST004** - Click `Add IDs` to confirm. The plates are listed in the added requests. - Click `Next` ### Task Requesting - Choose Reformatting Mode = **Combine Source** - Target Quadrant = **1** - Target Usage = **Inventory** - Select Number of Copy = **2** - Target Volume = **30 μl** - Dilution = **Target** - Dilution Mode = **Dilution Factor** - Dilution Factor = **10** - Buffer (Solvent) = **DMSO** - Offset Volume = **0 %** - Offset Solvent = **0 %** - Click `Add Task`. *Repeat these settings for quadrants 2, 3, and 4.* The “Combine Source” option will follow the sources plates in the order they were added. Here, the process will make a transfer from the first well of PTEST001 into the corresponding quadrant 1 of the new 384-well plate, then from the first well of PTEST002 into the quadrant 2, and so on (see figure in Introduction). Note the order you define plate requesting impacts the generated worklist. Example - PTEST001 is requested before PTEST002, so PTEST001 and PTEST002 will be transferred in the quadrant 1 and quandrant 2 respectively. Compared to the other option (see the Reformatting – Combine Replicate tutorial), this offers better control over the order of the samples in the target 384-well plate. - Click the `Next` button. ### Sourcing Plates are successfully sourced if the requested tasks are compatible (e.g. sufficient volume). All Plates (PTEST001 to PTEST004) should be sourced. - Click `Next` ### Processing - Select the **Standard (Container) (;)** equipment and **By Request** for File Order - Click `Generate worklist` A worklist file appears in the Worklist Generator area. It contains the requested tasks to execute. The Worklist Parser area expects a file containing the information about the tasks that were actually completed. By default, the generated file is set in the Worklist Parser. For this tutorial, we assume that every task was completed successfully, so we’ll keep this default file. - Click `Copy Worklist` - Click `Next` to propagate those changes in the system. The tasks are processed in the Sample application. ### Storing The [Storing step](/public/docs/jobs-overview#storing) allows you to assign a location to the items involved in the job. First, for the output plate (plate created during the job). - Click `Assign Location to Selected` - Select **Paris > HTS Lab** and click `Select` to confirm your choice. - Click `Next` to continue to the input plates. Here, we won’t change the input plates location. - Click `Next` You can increment the Thawing Cycle count of the input plates if necessary. ### Pipe & Close The [Pipe & Close step](/public/docs/jobs-overview#pipe-close) provides a summary page where you can review the job and optionally pipe it to another workflow. You can also pipe this job to another one, allowing you to immediately start a new job using the output or the input plates from this one. For this tutorial, click the `Close & Quit` button to finish the job.